This page prepares a V-SOL GPON OLT, such as the V1600G series, the V1600GT or the V1600GS-F, or a V-SOL EPON OLT, such as the V1600D series, for SmartOLT. You connect to the OLT, check its model and firmware, set a management IP address, create a user for SmartOLT and allow Telnet and SNMP in the login access list. After these steps, you connect the OLT to SmartOLT.
1Connect to the OLT
Click to choose how you connect to the OLT
- Ethernet / Telnet or SSH: a network cable to the AUX management port of a factory-new OLT, or the network path of an OLT you can already reach.
- Serial / Console: a serial cable to the CONSOLE port. Use it when you do not know the IP address or remote access does not work.
- Web interface: a network cable, as for Ethernet, and a web browser.
V-SOL OLTs with a single PON port have no AUX port. Use their USB-C console port, or connect to a GE port.
Ethernet connection (Telnet or SSH)
- On a factory-new OLT, connect an Ethernet cable to the AUX port. This is the out-of-band management port. It is for management only and cannot carry customer traffic. If the OLT is already reachable over your network, keep the existing cabling.
- When you connect directly to the factory IP, configure 192.168.8.1/255.255.255.0 on your PC, or on the MikroTik port connected to the AUX port.
- Verify connectivity. You should receive replies.
ping [OLT IP address]ping 192.168.8.200 - Connect with PuTTY or from a terminal, using Telnet or SSH.
Telnet sends everything, including the password, as plain text. Use it only on a direct cable or a trusted management network. In PuTTY, select Telnet and enter the OLT IP address.
telnet [OLT IP address]telnet 192.168.8.200SSH encrypts the session. It works only if the SSH server is enabled on the OLT and the account is allowed to log in over SSH.
PuTTY: Enter the OLT IP address in Host Name (or IP address), select SSH, then click Open. Log in with your OLT username and password.
Terminal (OpenSSH): Run the command below in your computer's terminal.
ssh [username]@[OLT IP address]ssh admin@192.168.8.200 - Log in with the admin account. On a factory-new OLT, the default password is Xpon@Olt9417#. If it does not work, use the password supplied by V-SOL with the device. On an OLT that is already configured, use its existing account.
############################################################ # # # Welcome to GPON OLT Platform. # # # # Press Return to connect and config this system. # # # ############################################################ User Access Verification Login: admin Password: gpon-olt>
If you cannot log in, or Telnet and SSH do not answer, use the serial console method.
Serial / Console connection
From a PC (PuTTY)
- Connect the serial cable supplied with the OLT to the CONSOLE port.
- If your PC has no serial port, use a USB-to-serial adapter.
- Find the COM port of the adapter in Windows Device Manager (Windows+X), under Ports (COM & LPT).
- In PuTTY, select Serial, enter the COM port and the speed. Set the other values under Connection > Serial:
- Speed: 115200, 57600 or 9600, depending on the OLT model. If the console shows garbled text or nothing, try the next speed.
- Data bits: 8
- Parity: None
- Stop bits: 1
- Flow control: None
- Open the session and press Enter. Log in with the OLT account. On a factory-new OLT, the default user is admin and the default password is Xpon@Olt9417#.
Through a MikroTik
If your MikroTik has an RJ45 CONSOLE port, connect it to the V-SOL CONSOLE port with a standard straight-through RJ45 (1:1) patch cable. This is a serial connection, so use the dedicated console ports at both ends. Open a MikroTik Terminal through WinBox or SSH over the network.
- Free the serial port and open the serial session:
/system console disable [find where port=serial0] /system serial-terminal serial0 - Press Ctrl+A, release the keys, then press R to detect the baud rate automatically. Press Enter to reach the OLT console.
To close the serial session, press Ctrl+A, release the keys, then press Q.
Web interface
The login page shows the firmware. The standard firmware and EPON OLTs show the first page below. The FRR firmware shows the second page and also asks for the verification code shown next to it.
- On a factory-new OLT, connect an Ethernet cable to the AUX port. An OLT with FRR firmware has no AUX port, so connect to a GE port instead. If the OLT is already reachable over your network, keep the existing cabling.
- When you connect directly to the factory IP, configure 192.168.8.1/255.255.255.0 on your PC, or on the MikroTik port connected to the OLT.
- In your browser, open https://192.168.8.200 on a GPON OLT or https://192.168.8.100 on an EPON OLT. On an OLT that is already configured, use its current IP address. Accept the certificate warning of the browser.
- Log in with the admin account. On a factory-new OLT, the default password is Xpon@Olt9417#. If it does not work, use the password supplied by V-SOL with the device. On an OLT that is already configured, use its existing account.


2Check the OLT model
gpon-olt>enable
Password:
gpon-olt#configure terminal
gpon-olt(config)#show version
gpon-olt(config)#show running-config
Take the exact model from the OLT label. In the configuration, interface gpon means GPON and interface epon means EPON.
The first line of the configuration shows the firmware. Skip the Current configuration: line, if present.
Standard firmware: starts with "!".
FRR firmware: starts with "frr version".
3Configure a new management IP address
FRR firmware has no AUX interface. Set the management IP address on a VLAN.
Select the interface of the management IP
gigabitEthernet 0/1.
interface aux
ip address 10.200.0.2 255.255.255.0
exit
These commands create the management VLAN, tag it on the uplink and assign the management IP. The VLAN interface takes the address in prefix format.
We do not recommend in-band management. If a loop on an ONU goes undetected and the upstream device shuts down the uplink port, you lose the connection to the OLT as well.
vlan 300
exit
interface gigabitEthernet 0/1
switchport mode hybrid
switchport hybrid vlan 300 tagged
exit
interface vlan 300
ip address 10.200.0.2/24
exit
If the uplink already carries customer VLANs in hybrid mode, skip switchport mode hybrid and only add the tagged VLAN. Allow the same VLAN as tagged on the connected router or switch port.
If you connected over Ethernet using the old IP address, reconnect on the new IP address 10.200.0.2.
Check which default route the OLT has now:
show ip route
The line that starts with 0.0.0.0 is the current default route. If it shows another gateway, delete it:
no ip route 0.0.0.0/0 [old gateway]
On the FRR firmware, a gateway set with ip gateway is deleted with:
no ip gateway
Add the default gateway and save the configuration:
ip route 0.0.0.0/0 10.200.0.1
write
The OLT confirms the save:
gpon-olt(config)#write
Configuration saved to /mnt/config/usrcfg.conf
The default route is entered in prefix format, 0.0.0.0/0, not 0.0.0.0/8 or 0.0.0.0/24.
Make sure the default gateway IP address 10.200.0.1 is already configured on your router.
Check again. The 0.0.0.0 line must show your gateway:
show ip route
S>* 0.0.0.0/0 [1/0] via 10.200.0.1, ethv0.300
Ping the gateway from the OLT to confirm the route works. You should receive replies.
ping 10.200.0.1
4Create a dedicated username/password
SmartOLT uses this username and password to connect to your OLT. The user needs the ADMIN role.
The enable password must be the same as the login password. SmartOLT has a single password field for V-SOL and uses it for both. With different passwords, SmartOLT logs in but cannot enter privileged mode.
user manager
user add smartoltusr login-password (enter a strong password)
user role smartoltusr admin enable-password (enter a strong password)
exit
exit
write
5Allow SmartOLT in the login access list
SmartOLT connects to the OLT over Telnet or SSH. It reads OLT data over SNMP. The login access list can block these connections.
Allow Telnet and SNMP from any address and save the configuration:
login-access-list permit telnet 0.0.0.0 0.0.0.0
login-access-list permit snmp 0.0.0.0 0.0.0.0
write
These commands change only Telnet and SNMP. Your rules for web and SSH stay as they are.
If you reach the OLT through port forwarding, allow the forwarded ports only from SmartOLT on your router, as in Getting started.
If SmartOLT cannot connect to the OLT later, turn off the list and save the configuration. This opens web and SSH too, so protect the OLT on your router first:
login-access-list disable
write
Only if SmartOLT connects over SSH. SmartOLT uses Telnet by default. If you keep Telnet, skip this part.
Allow SSH in the login access list:
login-access-list permit ssh 0.0.0.0 0.0.0.0
write
Standard firmware
If you connect SmartOLT over SSH, the OLT needs an RSA host key. If show running-config has no crypto key line, create one:
crypto key generate rsa usage-keys modulus 2048
write
FRR firmware
If you connect SmartOLT over SSH, turn on the SSH server:
sshd
sshd enable
exit
write
Configure the OLT in the web interface
With the web interface, these steps replace steps 2 to 5.
2Check the firmware
Standard firmware
The EPON web interface looks slightly different, but it has the same menus. Click Submit or Add after each change.
Open OLT Information > Device Information. Software Version shows the firmware. Take the exact model from the OLT label.

FRR firmware
Open Monitor > Overview. Software Version shows the firmware. Take the exact model from the OLT label.

3Set the management IP address
Standard firmware
Use the AUX port if you can. We do not recommend in-band management. If a loop on an ONU goes undetected and the upstream device shuts down the uplink port, you lose the connection to the OLT as well.
Out-of-band, AUX port: open System Configuration > AUX IP. Enter the IP address, the subnet mask and the gateway, then click Submit. If your computer is connected directly to the AUX port, give it a free IP address in the new subnet. Then open the web interface on the new IP address.

In-band, VLAN interface:
Open OLT Configuration > VLAN. Enter the management VLAN ID and click Add.

A new management VLAN. Open the VLAN Port tab. Select the VLAN, set the uplink port to Hybrid and Tag, leave the other ports on Forbidden, then click Submit. If the uplink port already carries customer VLANs, keep its mode and only select Tag for this VLAN.

The uplink port carries the management VLAN tagged. Open OLT Configuration > Route > IP. Select the VLAN, enter the IP address and the subnet mask, then click Submit.

The IP address on the management VLAN. Open Route > Static Route. If the Static Route Table already has a 0.0.0.0 route with another gateway, delete it in the Delete column. Enter 0.0.0.0 as Destination IP and as Destination Mask, enter the gateway, then click Add.

The default route to the gateway.
FRR firmware
The FRR firmware has no AUX port, so the management IP address goes on a VLAN.
Open Switch > VLAN and click Create. Enter the management VLAN ID and click Submit.

A new management VLAN. In the row of the new VLAN, click the edit icon. Set the uplink port to Hybrid and Tag, leave the other ports on Forbidden, then click Submit. If the uplink port already carries customer VLANs, keep its mode and only select Tag for this VLAN.

The uplink port carries the management VLAN tagged. Open Protocol > VLAN IP and click Create. Select the VLAN, enter the IP address and the mask, then click Submit.

The IP address on the management VLAN. Open System > Gateway, enter the gateway and click Submit. The Gateway field shows the current gateway.

The default gateway.
Allow the same VLAN as tagged on the connected router or switch port.
4Create a user for SmartOLT
Standard firmware
Open System Configuration > User Management. Enter a user name and a strong password twice, select Admin as User Role, then click Add. SmartOLT connects with this user and password.

FRR firmware
Open System > User Manage and click Create. Enter a user name and a strong password twice, select Admin as Role, then click Submit. SmartOLT connects with this user and password.

If SmartOLT cannot connect with this user, choose Ethernet / Telnet or SSH in step 1. Enter configuration mode as shown in step 2, then create the user with the commands of step 4.
5Allow SmartOLT in the login access list
Standard firmware
Open System Configuration > Login Management. Select Permit and ipv4, select Telnet as Protocol, enter 0.0.0.0 as Source IP and as IP Mask, then click Add. Add a second rule the same way for SNMP.

FRR firmware
Open System > Login Manage and click Create. Select Permit and IPv4, select Telnet as Protocol, enter 0.0.0.0 as Source IP and as Source IPv4 Mask, then click Submit. Add a second rule the same way for SNMP.

SmartOLT uses Telnet by default. To use SSH, add a third rule for SSH. Then choose Ethernet / Telnet or SSH in step 1, enter configuration mode as shown in step 2, and prepare SSH with the commands at the end of step 5.
If you reach the OLT through port forwarding, allow the forwarded ports only from SmartOLT on your router, as in Getting started.
Standard firmware
If SmartOLT cannot connect to the OLT later, set Login Access Status to Disable and click Submit. This opens web and SSH too, so protect the OLT on your router first.
FRR firmware
If SmartOLT cannot connect to the OLT later, turn off Login Access Status and click Submit. This opens web and SSH too, so protect the OLT on your router first.
6Save the configuration
Setup complete
At this stage, your OLT is ready to be interconnected with SmartOLT.
Open your SmartOLT site, go to Settings → OLTs → Add OLT, select V-SOL and the connection protocol (Telnet or SSH), fill in the fields displayed and click Save. For the details of each field and for Test connection, see Add an OLT and check its status.
Other settings
If you use SmartOLT, these settings are configured automatically. You do not need to configure them manually:
snmp-server community [READ COMMUNITY] ro
snmp-server community [WRITE COMMUNITY] rw
time zone [OFFSET]
time set year [Y] month [M] day [D] hour [h] minute [m] second [s]
ntp server 216.239.35.4 162.159.200.123
snmp-server host [SMARTOLT TRAP IP] udp-port 162 version 2c community [TRAP COMMUNITY]
alarm onu-port-los trap disable
event name user-login trap disable
event name user-logout trap disable
SmartOLT does not change ONU auto-learning on the OLT. You choose it for each PON port in SmartOLT, in OLT details > PON ports. With auto-learning on (GPON) or auth mode Disable (EPON), the OLT authorizes every new ONU by itself, and SmartOLT imports it within a few minutes. With auto-learning off (GPON) or auth mode MAC (EPON), new ONUs wait in the unconfigured list, and you authorize them in SmartOLT.